CONTACT US
13938857731

Contact:Xia Manager
Tel:0379-64310082
   0379-64310122
Fax:0379-64310122
Q Q:1491635964
Email:1491635964@qq.com
Address:Three Yuan Lu Luoyang City hi tech Development Zone No. three

Frequency induction heating equipment

High frequency induction heating equipment 120

Author: Published:2014-12-08 Views:1001

High frequency induction heating equipment 120

Technical parameters and characteristics:

The working power supply

三相四线制380V/50Hz

The cooling water flow rate (host)

15L/Min(0.1MPa)

Operating voltage range

342V~430V

The cooling water flow rate (transformer)

18L/Min(0.1MPa)

The maximum input current

120A(母线)

Cooling water pressure

0.1~0.3MPa

Oscillatory power

120KVA

Water temperature protection point

50℃

Oscillation frequency

30~150KHz

Host weight

140kg

Efficiency

90%

The weight of the transformer

89kg

Continuous load rate

100%

Machine dimensions (mm 3)

460×360×630

Timing

0.01s~99h

Transformer size (mm 3)

320×620×410


The use of the resonant inverter technology, high efficiency, power consumption is only one electron tube induction heating equipment, 20%-50%.
It is safe and reliable, compared with the tube device, no million volt, safe operation.
It adopts power MOS devices of inverter, high frequency, light weight, small size.
The fool type design, simple installation, convenient use, no need for debugging.